NEW QUESTION # 119
Which LED status indicates that System ID mode is active in a Dell PowerEdge R760 server?
- A. Blinking amber
- B. Blinking blue
- C. Solid white
- D. Solid blue
Answer: B
NEW QUESTION # 120
A technician is sent on-site to troubleshoot a server that halts during POST. The iDRAC System Event Log shows the following errors: A bus fatal error was detected on a component at bus 0 device 1 function
1 A bus fatal error was detected on a component at bus 1 device 0 function 0 CPU 1 has an internal error (IERR) The following system information is provided.
Which system component is the most likely cause?
- A. Network daughter card
- B. RAID controller
- C. Processor
- D. System board
Answer: D
NEW QUESTION # 121
What is the maximum number of local iDRAC users that can be created?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION # 122
A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR.
What action might be required to solve the alert?
- A. Swap the PERC controller
- B. Reseat the IDSDM
- C. Update the Intel driver
- D. Clear logs
Answer: C
NEW QUESTION # 123
A technician is ready to deploy a server. If a critical part such as the system board fails, they must be able to replace the system board, reconfigure components, and update the firmware revisions in the fastest possible time.
How should the technician meet this requirement?
- A. Use the iDRAC GUI to back up the Server Profile
- B. Use the iDRAC Rollback feature to restore the firmware revisions
- C. Back up the profile using the System Profile Settings
- D. Back up component configurations using iSM
Answer: A
NEW QUESTION # 124
A server is configured with a RAID 5 Virtual Disk across 5 hard disks and 1 spare disk. If a hard disk failure occurs within the RAID 5 virtual disk, the spare disk needs to be online as quickly as possible. It is acceptable for users to experience decreased performance during the rebuild procedure.
How should this requirement met?
- A. Change cache to Write Through
- B. Select Fast Rebuild
- C. Increase Rebuild Rate
- D. Enable Rebuild Priority
Answer: C
NEW QUESTION # 125
A technician deletes the iDRAC Enterprise license on a R640 server.
Which license type is then enabled?
- A. iDRAC will not have a license until a new one is installed
- B. iDRAC Basic license
- C. iDRAC Enterprise license cannot be deleted
- D. iDRAC Express license
Answer: B
NEW QUESTION # 126
A technician is configuring the server to boot to the Internal Dual SD Module.
Which BIOS boot option should the technician select?
- A. DVD-ROM
- B. Integrated NIC
- C. vFlash Media
- D. Hard Drive C
Answer: C
NEW QUESTION # 127
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?
- A. Virtualization Technology
- B. Number of Cores per Processor
- C. HyperThreading
- D. System Profile
Answer: B
NEW QUESTION # 128
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies. The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC.
What should the technician do to verify iDRAC connectivity on each server?
- A. iDRAC Datacenter license is installed.
- B. iDRAC Enterprise license is installed
- C. Ethernet port LOM1 is cabled and the link light is green
- D. iDRAC dedicated NIC port is cabled and the link light is green
Answer: D
NEW QUESTION # 129
A technician suspects that a firmware revision is corrupt. A newer revision is not available and the customer does not want to downgrade to a lower revision.
What should be done when troubleshooting for possible corrupt firmware?
- A. Upload the same firmware revision level
- B. Use the Lifecycle Controller Parts Replacement feature to bring the components up to the latest firmware revision levels
- C. Reset the iDRAC
- D. Disable and re-enable the component then reboot the server
Answer: A
NEW QUESTION # 130
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?
- A. Add the PowerEdge R430 PSU modules to the PowerEdge R440
- B. Configure the PowerEdge R440 PSU with 1+1 configuration
- C. Order a new PSU specific to the existing PowerEdge R440
- D. Add the PowerEdge R420 PSU modules to the PowerEdge R440
Answer: C
NEW QUESTION # 131
What is the Open Compute Project (OCP) card used for in a Dell EMC PowerEdge server?
- A. Consumes a PCIe slot
- B. Removal of NDC
- C. Fixed network interconnect
- D. Provides a hot-swap component
Answer: B
NEW QUESTION # 132
A technician is configuring a PowerEdge R640 that has two PSUs. The rack in which it is being installed has two power distribution units (PDUs). No high power such as GPUs are required. The user wants as must redundancy protection as possible.
What is the best way to configure the PSUs?
- A. Redundancy Mode set to 2+0 with each PSU power cord connected to a different PDU
- B. Redundancy Mode set to 1+1 with each PSU power cords connected to a different PDU
- C. Redundancy Mode set to 1+0 with the second PSU stored nearby for quick replacement if the first PSU fails
- D. Redundancy Mode set to1+1 with both PSU power cords connected to the same PDU
Answer: B
NEW QUESTION # 133
A company needs a server that meets these requirements:
- Support workloads that are accelerated and computational-heavy
- Has cyber resilient architecture and Root of Trust
- Supports HPR fans
- Supports OCP 3.0 technology
Which Dell PowerEdge server model meets these requirements?
- A. XE9680
- B. R960
- C. MX760c
Answer: A
NEW QUESTION # 134
A technician wants to install a new version of OMSA onto a server that already has an existing version of OMSA.
What is required for this new installation?
- A. iDRAC firmware needs to be at version 5.0 or higher
- B. Existing OMSA must be uninstalled before the new version is installed
- C. Existing OMSA version must be disabled in Services
- D. iSM must also be installed on the managed server
Answer: B
NEW QUESTION # 135
A technician needs to remotely update the iDRAC with Lifecycle Controller firmware. They have downloaded the latest iDRAC firmware to the management station and connected to the iDRAC GUI.
What step is required to complete the update?
- A. Boot the server into F10 to start the firmware update
- B. Go to the Firmware Update page and upload the iDRAC firmware
- C. Go to the Summary Page and reset the iDRAC
- D. Boot into the OS via Virtual Console and execute the firmware
Answer: B
NEW QUESTION # 136
A technician is remotely installing ESXi 6.0 on a PowerEdge R640 in BIOS boot mode. The system has dual internal SD cards. After the OS is installed, the system reboots and shows an error screen with the following message: "No boot device found" What should the technician do to resolve this issue?
- A. Enable vFlash in iDRAC web GUI
- B. Set the boot made from BIOS to UEFI
- C. Reseat the SD cards and try to boot to them again
- D. Change the Hard Disk Drive Sequence
Answer: A
NEW QUESTION # 137
Which component of the Dell EMC PowerEdge server provides system information, status, and error messages to indicate when the system is operating correctly, or when the system needs attention?
- A. Front Panel LCD
- B. RACADM
- C. BIOS
- D. UEFI
Answer: A
NEW QUESTION # 138
Which is responsible for controlling the NVMe disks, when using a Paddle Card in a PowerEdge 15G server?
- A. H745
- B. S150
- C. HBA355
Answer: B
NEW QUESTION # 139
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A. Install and configure a repository manager
- B. Configure servers to access the remote firmware repository
- C. Enable the Collect System Inventory On Restart (CSIOR) attribute
- D. Enable the Match Firmware of Replaced Part setting in the system BIOS
Answer: B
NEW QUESTION # 140
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights- out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials.
How could the technician change the iDRAC password?
- A. iDRAC Web GUI
- B. OpenManage Server Administrator
- C. SupportAssist Enterprise
- D. Virtual Console; press F2 after rebooting system
Answer: C
NEW QUESTION # 141
......