Unique Top-selling NS0-173 Exams - New 2022 Network Appliance Pratice Exam [Q13-Q30]

Share

Unique Top-selling NS0-173 Exams - New 2022 Network Appliance  Pratice Exam

Cisco and NetApp FlexPod Dumps NS0-173 Exam for Full Questions - Exam Study Guide


Network Appliance NS0-173 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Compute Hardware components, Configuration, High availability, SAN Boot, UCS Manager
Topic 2
  • Networking Hardware components, Configuration, High availability, SAN Boot
Topic 3
  • Storage Hardware components, Configuration, High availability, SAN Boot
Topic 4
  • Virtualization Hypervisor Solutions, SAN Boot

 

NEW QUESTION 13
A customer is planning to deploy a FlexPod solution for a large scale SAN requirement that uses the FC protocol. The customer plans to use Smart Zoning in the configurations to reduce the number of TCAM entries in the zoning process.
In this scenario, which design would enable the customer to use Smart Zoning?

  • A. storage connected to Cisco MDS switches
  • B. storage directly connected to Cisco UCS Fabric Interconnects
  • C. storage connected to Cisco Nexus 5000 Series switches
  • D. storage connected to Cisco Nexus 9000 Series switches

Answer: A

 

NEW QUESTION 14
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. Cluster mode
  • B. Multipath mode
  • C. DualWire Management mode
  • D. Direct Connect mode
  • E. SingleConnect mode

Answer: C,D,E

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 15
What are characteristics of the Cisco UCS 5108 blade chassis?

  • A. 4 RU, 8 half-width UCS B-series blades, 40 Gbps I/O bandwidth
  • B. 4 RU, 6 half-width UCS B-Series blades, 160 Gbps I/O bandwidth
  • C. 6 RU, 6 half-width UCS B-series blades, 80 Gbps I/O bandwidth
  • D. 6 RU, 8 half-width UCS B-series blades, 160 Gbps I/O bandwidth

Answer: D

 

NEW QUESTION 16
After you install a FlexPod infrastructure at a customer site, you need to migrate the existing Vmware virtual machines off the infrastructure that was used before FlexPod was installed.
Which VMware vSphere feature accomplishes this task?

  • A. vSphere HA
  • B. vSphere DRS
  • C. VM Component Protection
  • D. vMotion

Answer: D

 

NEW QUESTION 17
A client has a FlexPod Datacenter solution with four active fabric links in port channel mode established between the Cisco Fabric Interconnects and the IOMs on a Cisco 5108 blade chassis. The blade chassis is fully populated with Cisco UCS B200M5 blades. A worker in the data center inadvertently unplugs the fourth uplink cable from IOM-A while working in the rack.
In this scenario, what happens to the network traffic?

  • A. Connectivity for servers 3, 4, 7, and 8 all fail over to IOM-B.
  • B. There is a loss of connectivity for servers 4 and 8.
  • C. Traffic is load-balanced within IOM-B.
  • D. Traffic is load-balanced within IOM-A.

Answer: A

 

NEW QUESTION 18
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?

  • A. uplink port
  • B. server port
  • C. appliance port
  • D. monitor port

Answer: A

 

NEW QUESTION 19
Which port type would you configure when you connect a chassis to the Cisco Fabric Interconnects?

  • A. server ports
  • B. FC storage ports
  • C. appliance ports
  • D. Ethernet uplink ports

Answer: B

 

NEW QUESTION 20
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)

  • A. a two-node FAS8200 with a 4 TB NL-SAS HDD
  • B. a DS4246 with twenty-four 6 TB NL-SAS HDDs
  • C. a DS224C with twenty-four 3.8 TB SSDs
  • D. a two-node AFF A200 with a 3.8 TB NSE SSD

Answer: A,C

 

NEW QUESTION 21
You want to deploy a FlexPod Datacenter solution based on the minimum hardware requirements.
Which three components must be deployed in highly available pairs to accomplish this task? (Choose three.)

  • A. NetApp FAS Storage Controllers
  • B. Cisco APICs
  • C. Cisco UCS Fabric Interconnects
  • D. Cisco UCS 5108 Chassis
  • E. Cisco USC Nexus Switches

Answer: A,C,D

 

NEW QUESTION 22
A customer wants to deploy a performance-sensitive workload while leveraging NetApp Snapshot technology and technologies such as NAS and SAN.
Which architecture satisfies these requirements?

  • A. NetApp EF-Series
  • B. NetApp StorageGRID
  • C. NetApp SolidFire
  • D. NetApp AFF

Answer: C

 

NEW QUESTION 23
A customer with a FlexPod Express configuration is currently operating Linux servers. The company wants to move to a Windows-centralized access method for the NetApp storage component.
In this scenario, which two ONTAP features must be configured? (Choose two.)

  • A. Active Directory security model
  • B. SVM with the NFS protocol enabled
  • C. SVM with the SMB protocol enabled
  • D. Workgroup security model

Answer: A,C

 

NEW QUESTION 24
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
Which tool satisfies the requirements of this customer's heterogeneous environment?

  • A. NetApp OnCommand Unified Manager
  • B. NetApp OnCommand Insight
  • C. UCS Central
  • D. UCS Director

Answer: D

 

NEW QUESTION 25
Which two NetApp storage controllers would be used in a valid FlexPod Datacenter configuration? (Choose two.)

  • A. NetApp EF570
  • B. NetApp FAS2700
  • C. NetApp AFF A700
  • D. NetApp E2800

Answer: B,C

 

NEW QUESTION 26
Click the Exhibit button.

You have designed a FlexPod Express solution that uses a NetApp ONTAP controller, Cisco UCS C-Series servers, and Cisco Nexus 3000 Series switches, as shown in the exhibit. Which three storage protocols are supported in this design? (Choose three.)

  • A. FC
  • B. iSCSI
  • C. NFS
  • D. FCoE
  • E. SMB

Answer: A,B,C

 

NEW QUESTION 27
A customer is configuring the UCS to handle a multitenant environment. The customer has created an organization within UCS for each tenant and would like to allow access to these organizations for only users that belong to that tenant.
In this scenario, which feature in UCS Manager should the customer use to accomplish this task?

  • A. Locales
  • B. User Roles
  • C. Service Profile
  • D. Trusted Platform Module

Answer: C

 

NEW QUESTION 28
You are asked to design a FlexPod solution that meets the minimum requirements and includes Application Centric Infrastructure (ACI).
Which three Cisco components are required in this scenario? (Choose three.)

  • A. Cisco Nexus 2000 Series Fabric Extender
  • B. Cisco Nexus 3000 Series switches
  • C. Cisco UCS Series Fabric Interconnects
  • D. Cisco UCS B-Series servers
  • E. Cisco Nexus 9000 Series switches

Answer: C,D,E

 

NEW QUESTION 29
The storage administrator must change the vHBA settings bound to a template associated with a production server.
What happens when the settings are reconfigured in this scenario?

  • A. The service profile template that is associated with the server is initialized.
  • B. The vHBA template is deleted from UCS Manager.
  • C. The server that is associated with the service profile reboots.
  • D. The vHBA configuration change does not affect LUN access.

Answer: A

 

NEW QUESTION 30
......

Best way to practice test for Network Appliance NS0-173: https://www.itexamsimulator.com/NS0-173-brain-dumps.html